DIP Switch SW11 = "up" for this mode.
In speed sensing mode, the relay will activate for approximately 1 second when the sensed RPM is equal to or greater than the RPM threshold. DIP Switches SW1 to SW10 are used to set the threshold value. The output relay has both normally open and normally closed contacts available to the user.
The CPR of the encoder must be chosen according to the desired RPM range:
ENCODER CPR |
RPM RANGE |
200 |
28 to 7004 |
256 |
21 to 5470 |
512 |
11 to 2736 |
1024 |
6 to 1268 |
DIP switch SW10,SW9,SW8 setting:
Calculate the PRESET value from the desired RPM threshold, RPMT and the encoder CPR using the formula:
PRESET = 1920 / (RPMT * CPR)
Look up the SW10/SW9/SW8 setting based on the PRESET value using the table below and note the corresponding PREOUT constant value. If PRESET is outside the range of the table, lower the encoder CPR to get the value within range.
PRESET RANGE |
SW10 |
SW9 |
SW8 |
PREOUT |
0.1747601 to 0.3495300 |
↓ |
↓ |
↓ |
0.3495300 |
0.0873811 to 0.1747600 |
↓ |
↓ |
↑ |
0.1747600 |
0.0436911 to 0.0873810 |
↓ |
↑ |
↓ |
0.0873810 |
0.0218451 to 0.0436910 |
↓ |
↑ |
↑ |
0.0436910 |
0.0109231 to 0.0218450 |
↑ |
↓ |
↓ |
0.0218450 |
0.0054614 to 0.0109230 |
↑ |
↓ |
↑ |
0.0109230 |
0.0027308 to 0.0054613 |
↑ |
↑ |
↓ |
0.0054613 |
0.0000000 to 0.0027307 |
↑ |
↑ |
↑ |
0.0027307 |
DIP Switch SW7 to SW1 setting:
Calculate the offset value as shown below:
OFFSETV = ( (RPMT * CPR * PREOUT) / 15 ) - 128
Convert the OFFSETV to binary and enter the value on SW7 to SW1. SW7 is the most significant bit. DIP Switch down = 0 and DIP Switch up = 1